VGSM Technology (M)
Sdn Bhd
No.34G, 34A & 34B, Lorong Perda Selatan 1, Bandar Perda, 14000 Bukit Mertajam, Penang, Malaysia.
 +604-538 1998
+604-530 1998
 sam_vgsm@vgstech.com.my

AZIMUTH CNC CMM (Large Volume)

Previous 7 / 8 Next

AZIMUTH CNC CMM (Large Volume) CMMs and Vision System ABERLINK Coordinate Measuring Machine (CMM) Series


Aberlink Azimuth CNC CMM
Azimuth... from strength to strength

As CMMs get larger, it is not simply a case of scaling up the design of smaller models. Stiffness of the structure is critical, but weight must also be kept to a minimum.The Azimuth CMM is not only Aberlink’s largest in their range of CMM products, but it is the culmination of over twenty years experience and excellence in the design and manufacture of innovative metrology equipment incorporating the very latest materials technology.

The revolutionary bridge of the Azimuth incorporates aluminium honeycomb sheets developed for use in formula one and the aerospace industry. The remarkable stiffness to weight ratio that this provides gives the Azimuth an edge in both performance and speed. For a machine of this size, the Azimuth is not only fast, but extremely accurate.

The drive systems designed for the Azimuth offer simplicity and reliability and the novel system used on the Y axis ensures that there is no degradation of performance across the full range of machine sizes offered up to 3m.

A big machine should also be able to measure a heavy component and this is another area where Aberlink have applied innovative thinking. Rather than simply increasing the depth of the granite table, which adds huge cost and weight to the machine, we offer a specially designed load plate to sit on the granite base. This plate can accept up to a six tonne load which will then be transmitted directly through the feet of the machine bench directly to the floor, meaning no loss of metrology performance whatsoever – just another really clever idea!


Technical Information:

*Maximum Permissible Error MPEE according to 10360-2, 2009 within the thermal limits defined for optimum temperature range.
**Installation environment thermal limits: Rate of change <1°C/hr and <2°C/24hr. Temperature gradient <1°C/m
Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Recent Updates
Subscribe Newsletter
1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start